Basic Info.
Model NO.
High Voltage Cable
Type
Conductor Type
Stranded
Application
Conductor Material
Sheath Material
Insulation Material
Material Shape
Round Wire
Certification
ISO9001, CE, CCC
Conductor
Aluminum or Copper
Brand Name
OEM
Transport Package
Wooden Drum (Customer Requirement)
Origin
China
Product Description
XLPE Insulation Power Cable of 26/35KV or Lower
The cable is used to transmit power on the power transmission and distribution line of AC. 50Hz, rated voltage 35KV or lower. By comparison with power cable with PVC insulation, it has not only excellent electric performance, mechanical performance, heat&aging resistant performance, weather resistant performance, chemical corrosion resistant performance, but also simple structure, light wight, no restriction by laying drop, and high temperature allowance for long term working(90ºC)as well.
Executive standard
As section"extruded insulation power cable with rated voltage from 1KV(Um=1.2KV) to 35KV(Um=40.5 KV)" stipulated in GB/T12706.1-2008~GB/T12706.3-2008 or IEC60502 according to the requirement of the customer.
Working Condition
1. Long-term working temperature by cable conductor is 90ºC.
2. Max.temperature of cable conductor shall be no more than 250ºC during short circuit(the longest lasting time shall be no more than 5 seconds.)
3. Environment temperature for installation is no less than 0ºC.
4. Min bending radium of cable
5. A.C.rated voltage Uo/U of cable is 0.6/1KV-26/35KV.
Uo: rated A.C. Voltage of conductor to earth or between metallic shielding for cable designing, which is called phrase voltage.
U: rated A.C. Voltage between conductor for cable designing, which is called wire voltage.
Type, description and application Occasion
Note:1. Except for these types, there are basic types fellow: YJY22, YJLY22, YJV62, YJLV62, YJY62, YJLY62, YJY23, YJLY23, YJV63, YJLV63, YJY63, YJLY63, YJY32, YJLY32, YJY42, YJLY42,YJV72, YJLV72, YJY72, YJLY72, YJY33, YJLY33. YJY43, YJLY43, YJV73, YJLV73, YJY73, YJY73,etc;For 0.6/1KV and 1.8/3KV cable, and halogen-free low-smoke fire-retardant cable: WDZC(YJY,YJLY,YJY23,YJLY23,YJY33,YJLY33,YJY43,YJLY43),etc.
2.Cables that can produce as customers require.
2.1 Fire-retardant cable for all grades. Add "ZA""ZB"or"ZC"in the front. A, B, C stand for grade. When there is no require of fire-retardant for this cable, we fellow the grade C, and add ZR in the front. These types are in accordance with this standard and GB/T 19666-2005
2.2 halogen-flee low-smoke fire-retardant cables. Fit for all grades of non-PVC inner sheath/outer sheath cable, add WDZ(A,B,C) in the front. These types are in accordance with this standard and GB/T 19666-2005
2.3 Fire-resistant electric cable(0.6/1KV and 1.8/3KV)Add "NA", "N"in the front."NA"stand for grade A ,"B"stand for grade B. Only copper core for Fire-retardant electric cable. When no requirement, we fellow grade B. Add"NH"in the front. These types are in accordance with this standard and GB/T 19666-2005 and GB/T19216.21-2003.
2.4 Fire-resistant and flame-retardant electric cable/halogen-flee low-smoke fire-retardant electric cables(0.6/1KV and 1.8/3KV) Expressed as "Z(A,B,C)N-", "WDZ(A,B,C)N-", fellow 2.1,2.2 and 2.3. These types are in accordance with this standard and GB/T19666-2005 and GB/T 19216.21-2003
2.5 Waterproof, rat proof, termite proof and UV resistant cable.
2.6 EMI shielding cable.
2.7 All kinds of special use cables.
3. For AC system, normally use nonmagnetic material armour to reduce magnetism loss.
Production Scope
we guarantee that:
1. Customer is God. We will cherish every client, every cooperation by heart.
2. Free pre-sales service. We will provide best proposal for each client.
3. Good sales service. We will provide free relative product operation, maintenance tips and installation commissioning
technical advisory service when establish cooperation relationship with clients.
4. Thoughtful after sales service . We guarantee solve your problems within 48 hours.
6. 24 hours hot-line telephone service. We will appoint professional person answer your question timely.
certificate
Packing &shipment
The Equipment
Workshop
The cable is used to transmit power on the power transmission and distribution line of AC. 50Hz, rated voltage 35KV or lower. By comparison with power cable with PVC insulation, it has not only excellent electric performance, mechanical performance, heat&aging resistant performance, weather resistant performance, chemical corrosion resistant performance, but also simple structure, light wight, no restriction by laying drop, and high temperature allowance for long term working(90ºC)as well.
Executive standard
As section"extruded insulation power cable with rated voltage from 1KV(Um=1.2KV) to 35KV(Um=40.5 KV)" stipulated in GB/T12706.1-2008~GB/T12706.3-2008 or IEC60502 according to the requirement of the customer.
Working Condition
1. Long-term working temperature by cable conductor is 90ºC.
2. Max.temperature of cable conductor shall be no more than 250ºC during short circuit(the longest lasting time shall be no more than 5 seconds.)
3. Environment temperature for installation is no less than 0ºC.
4. Min bending radium of cable
5. A.C.rated voltage Uo/U of cable is 0.6/1KV-26/35KV.
Uo: rated A.C. Voltage of conductor to earth or between metallic shielding for cable designing, which is called phrase voltage.
U: rated A.C. Voltage between conductor for cable designing, which is called wire voltage.
Type, description and application Occasion
| Model Number | Description | Application |
| YJV | Copper Conductor, XLPE Insulated, PVC Sheathed Power Cable | For laying indoors,in tunnels or cable trench.Able to bear certain traction during installation, but not external mechanical forces. Laying single core cable in magnetic ducts is not allowed. |
| YJLV | Aluminum Conductor, XLPE Insulated, PVC Sheathed Power Cable | |
| YJY | Copper Conductor, XLPE Insulated, PE Sheathed Power Cable | |
| YJLY | Aluminum Conductor, XLPE Insulated, PE Sheathed Power Cable | |
| YJV22 | Copper Conductor, XLPE Insulated,Steel Tape Armored, PVC Sheathed Power Cable | For laying in doors,in tunnels,cable trench or direct in ground, Able to bear external mechanical forces but unable to bear large pulling forces. |
| YJLV22 | Aluminum Conductor, XLPE Insulated,Steel Tape Armored, PVC Sheathed Power Cable | |
| YJV23 | Copper Conductor, XLPE Insulated, Steel Tape Armored, PE Sheathed Power Cable | |
| YJLV23 | Aluminum Conductor, XLPE Insulated, Steel Tape Armored, PE Sheathed Power Cable | |
| YJV32 | Copper Conductor, XLPE Insulated, Fine Steel Wire Armored, PVC Sheathed Power Cable | For laying in doors,in tunnels,cable trench,well or direct buried,able to bear external mechanical forces and determinate pulling force, but can not suffer a lot of radial pressure. |
| YJLV32 | Aluminum Conductor, XLPE Insulated, Fine Steel Wire Armored, PVC Sheathed Power Cable | |
| YJV33 | Copper Conductor, XLPE Insulated,fine steel wire armored,PE Sheathed Power Cable | |
| YJLV33 | Aluminum Conductor, XLPE Insulated, fine steel wire armored,PE Sheathed Power Cable | |
| YJV42 | Copper Conductor, XLPE Insulated, Thick Steel Wire Armored, PVC Sheathed Power Cable | |
| YJLV42 | Aluminum Conductor, XLPE Insulated, Thick Steel Wire Armored, PVC Sheathed Power Cable | |
| YJV43 | Copper Conductor, XLPE Insulated, Thick steel wire armored,PE Sheathed Power Cable | |
| YJLV43 | Aluminum Conductor, XLPE Insulated, Thick steel wire armored,PE Sheathed Power Cable |
2.Cables that can produce as customers require.
2.1 Fire-retardant cable for all grades. Add "ZA""ZB"or"ZC"in the front. A, B, C stand for grade. When there is no require of fire-retardant for this cable, we fellow the grade C, and add ZR in the front. These types are in accordance with this standard and GB/T 19666-2005
2.2 halogen-flee low-smoke fire-retardant cables. Fit for all grades of non-PVC inner sheath/outer sheath cable, add WDZ(A,B,C) in the front. These types are in accordance with this standard and GB/T 19666-2005
2.3 Fire-resistant electric cable(0.6/1KV and 1.8/3KV)Add "NA", "N"in the front."NA"stand for grade A ,"B"stand for grade B. Only copper core for Fire-retardant electric cable. When no requirement, we fellow grade B. Add"NH"in the front. These types are in accordance with this standard and GB/T 19666-2005 and GB/T19216.21-2003.
2.4 Fire-resistant and flame-retardant electric cable/halogen-flee low-smoke fire-retardant electric cables(0.6/1KV and 1.8/3KV) Expressed as "Z(A,B,C)N-", "WDZ(A,B,C)N-", fellow 2.1,2.2 and 2.3. These types are in accordance with this standard and GB/T19666-2005 and GB/T 19216.21-2003
2.5 Waterproof, rat proof, termite proof and UV resistant cable.
2.6 EMI shielding cable.
2.7 All kinds of special use cables.
3. For AC system, normally use nonmagnetic material armour to reduce magnetism loss.
Production Scope
| Type | Core No. | Rated voltage | ||||||||
| 0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/20 | 21/35 | 26/35 | ||
| YJ(L)V YJ(L)Y YJ(L)V22 YJ(L)V23 YJ(L)V32 YJ(L)V33 YJ(L)V42 YJ(L)V43 | 1 | 1.5~800 | 10~800 | 10~630 | 16~630 | 25~630 | 35~630 | 50~630 | 50~630 | 50~630 |
| 3 | 1.5~400 | 10~400 | / | / | / | / | / | / | / | |
| 2 | 1.5~400 | 10~400 | / | / | / | / | / | / | / | |
| 3+1 | 1.5~400 | 10~400 | / | / | / | / | / | / | / | |
| 3+2 4+1 | 1.5~400 | 10~400 | / | / | / | / | / | / | / | |
| 5 | 1.5~400 | 10~400 | / | / | / | / | / | / | / | |
1. Customer is God. We will cherish every client, every cooperation by heart.
2. Free pre-sales service. We will provide best proposal for each client.
3. Good sales service. We will provide free relative product operation, maintenance tips and installation commissioning
technical advisory service when establish cooperation relationship with clients.
4. Thoughtful after sales service . We guarantee solve your problems within 48 hours.
6. 24 hours hot-line telephone service. We will appoint professional person answer your question timely.